Formaldehyde/Steam Sterilizers
This range of ERNA sterilizers combines steam sterilization with the low temperature steam and formaldehyde (LTSF) sterilization of heat-sensitive items. Combining two sterilization methods into single equipment increases the efficiency incredibly.
Formaldehyde / Steam sterilizers are designed especially for the Central Sterilization Departments. ERNA’s wide range of dimensions helps to meet different needs of the hospitals. The sterilizer is designed to meet the highest standards of safety.
Automatic unit commands and controls all the sterilization process and parameters with an industrial type of microprocessor, PLC. Once the Steam or FO mode is selected, it is possible to operate the sterilizer as if it is steam or FO sterilizer. Mode can be changed in a short time.
Highlights of ERNA Formaldehyde & Steam Sterilizers
- Temperature range: 650C – 750C (Formaldehyde mode) -1210C – 1340C (Steam mode)
- Sterilization agent: 2% Formaldehyde Solution(Formaldehyde mode), – Saturated steam(Steam Mode)
- Lower operating cost
- Delicate Heating With Steam
- Water Ring Vacuum Pump
- Chamber : S/S 316L Quality and Heating Jacket : S/S 304L
- Vertically Sliding Door(s) with Optional Automatic Door(s)
- Pass Through models are available
- Air Filter (0.2 Micron)
- Stainless Steel Piping in steam & formaldehyde gas lines.
Formaldehyde Sterilization Parameters
Superior quality ERNA Formaldehyde Sterilizers vary between 128 lt – 549 lt. and are manufactured as horizontal and vertical models. For each model single as well as double door options are available
- AISI 316L chamber with 10 years of warranty
- High quality spare parts with renowned brands
- Reliable automatic control with PLC
- Easy manual operation by touch panel
- Validated programs
- Alphanumeric printer
- Independent recorder (optional)
- Water ring type vacuum pump
- Pneumatic valves
- 2% Formaldehyde solution as sterilizing agent in bags
- Delicate heating with steam under vacuum
- Full-fledged technical service
- Complied with EN 14180
- Certified according to 93/42/EEC and 97/23/EC or ASME certified chamber (optional)
- Upon request combined model of steam and formaldehyde sterilizer can be manufactured
Specifications
- Automatic and the double door options are available for the models above
- Chamber depth is increased by 5 cm for the double-door models
- Standard chamber dimensions may be altered by 5% according to the customer requirements.
- Standard external sizes may be adjusted as per installation site specifications